Phoenix Contact
Showing 2961–2976 of 4585 results
-

2902725 Phoenix Contact – Safety relays – PSR-SCP- 24DC/MXF1/4X1/2X2/B Multifunctional safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, plug-in screw terminal block
-

2902726 Phoenix Contact – Safety relays – PSR-SPP-24DC/MXF1/4X1/2X2/B Multifunctional safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, plug-in spring-cage terminal block
-

2902744 Phoenix Contact – Hybrid motor starter – ELR H51-IESSC-24DC500AC-2 Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD and EM-RI adapters or power distribution board.
-

2902745 Phoenix Contact – Hybrid motor starter – ELR H51-IESSC-24DC500AC-9 Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 9 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD adapter, EM-RI adapter or power distribution board.
-

2902746 Phoenix Contact – Hybrid motor starter – ELR H51-IESSC-24DC500AC-06 Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 0.6 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD and EM-RI adapters or power distribution board.
-

2902776 Phoenix Contact – Adapter – EM SWD-ADAPTER SmartWire DT adapter for CONTACTRON hybrid motor starters, with “Enable” input for safe shutdown up to PLe/SIL 3.
-

2902811 Phoenix Contact – RAD-DO8-IFS Radioline – I/O extension module, 8 digital transistor outputs (30.5 V DC/200 mA)
-

2902814 Phoenix Contact – Configuration memory – RAD-CONF-RF3 Radioline – configuration stick for easy and safe network addressing for the 2.4 GHz wireless module (RAD-2400-…), unique network ID, RF band3
-

2902815 Phoenix Contact – Configuration memory – RAD-CONF-RF5 Radioline – configuration stick for easy and safe network addressing for the 2.4 GHz wireless module (RAD-2400-…), unique network ID, RF band5
-

2902816 Phoenix Contact – Configuration memory – RAD-CONF-RF7 Radioline – configuration stick for easy and safe network addressing for the 2.4 GHz wireless module (RAD-2400-…), unique network ID, RF band7
-

2902822 Phoenix Contact – Constant voltage source – MINI MCR-SL-CVS-24-5-10-NC Constant voltage source, input voltage 9.6 – 30 V DC, output voltage 10 V, 7.5 V, 5 V, 2.5 V DC, electrically isolated, can be configured via DIP switches, screw connection technology, standard configuration
-

2902823 Phoenix Contact – Constant voltage source – MINI MCR-SL-CVS-24-5-10-SP-NC Constant voltage source, input voltage: 9.6VDC…30VDC, output voltage: 10V, 7.5V, 5V, 2.5VDC, electrically isolated, can be configured via DIP switches, spring-cage connection technology, standard configuration. Replacement part: 2902065 MINI MCR-2-CVCS-PT.
-

2902828 Phoenix Contact – Configuration memory – RAD-MEMORY Radioline – memory stick for saving custom configuration data
-

2902829 Phoenix Contact – Signal conditioner – MINI MCR-SL-UI-I-LP-NC 2-way loop-powered isolating amplifier (supplied on the output side), can be configured via DIP switches, with screw connection technology and standard configuration.
-

2902830 Phoenix Contact – Signal conditioner – MINI MCR-SL-UI-I-LP-SP-NC Output-side-powered 2-way loop-powered signal conditioner, can be configured via DIP switches, with spring-cage connection technology, standard configuration. Replacement part: 2902063 MINI MCR-2-UI-I-OLP-PT.
-

2902832 Phoenix Contact – Frequency transducer – MINI MCR-SL-F-UI-NC The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Screw connection, standard configuration.