Phoenix Contact
Showing 3985–4000 of 4585 results
-

2924249 Phoenix Contact – Isolation amplifier – MACX MCR-EX-SL-2NAM-R-UP-SP 2-channel Ex-i NAMUR isolation amplifier with wide-range power supply for proximity sensors and switches. Every channel has a relay with PDT contact as a signal output. Line fault detection (LFD), 3-way isolation, SIL 2.
-

2924252 Phoenix Contact – Isolation amplifier – MACX MCR-SL-NAM-R-SP NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using relay output (PDT). Line fault detection (LFD), galvanic 3-way isolation, SIL 2, with push-in connection.
-

2924265 Phoenix Contact – Isolation amplifier – MACX MCR-SL-NAM-2RO-SP NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, Push-in connection.
-

2924281 Phoenix Contact – Isolation amplifier – MACX MCR-SL-2NAM-T-SP NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
-

2924294 Phoenix Contact – Isolation amplifier – MACX MCR-SL-2NAM-RO-SP NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
-

2924304 Phoenix Contact – MACX MCR-SL-2NAM-R-UP-SP 2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
-

2924320 Phoenix Contact – Temperature measuring transducer – MACX MCR-SL-RTD-I-SP-NC Temperature transducer, converts signals from resistance thermometers and resistors into 0/4 – 20 mA signals. Freely programmable, 3-way electrical isolation.
-

2924346 Phoenix Contact – Temperature measuring transducer – MACX MCR-SL-TC-I-NC Temperature transducer, converts signals from thermocouples and linear mV sources into 0/4-20 mA signals. Freely programmable, 3-way electrical isolation, custom-configured.
-

2924676 Phoenix Contact – Signal isolator – MACX MCR-EX-SL-RPSS-2I-2I-SP Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4¦20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3, PL.
-

2924689 Phoenix Contact – Temperature measuring transducer – MACX MCR-EX-T-UI-UP-SP Programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
-

2924799 Phoenix Contact – Temperature measuring transducer – MACX MCR-EX-T-UIREL-UP-SP Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
-

2924825 Phoenix Contact – Repeater power supply – MACX MCR-SL-RPSSI-2I Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4¦20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, screw connection, SIL, PL.
-

2924838 Phoenix Contact – Repeater power supply – MACX MCR-SL-RPSSI-2I-SP Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4¦20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, Push-in connection, SIL, PL.
-

2924867 Phoenix Contact – Solenoid driver – MACX MCR-EX-SL-SD-23-48-LFD Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, , line fault transparency, error message output, up to SIL 3 according to IEC 61508, screw connection
-

2924870 Phoenix Contact – Signal isolator – MACX MCR-EX-SL-SD-23-48-LFD-SP Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, , line fault transparency, error message output, up to SIL 3 according to IEC 61508, Push-in connection
-

2926250 Phoenix Contact – Cable – CABLE-D-37SUB/F/OE/0,25/S/2,0M Assembled shielded round cable connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.) connection 2: D-SUB socket strip (1x 37-position) cable length: 2 m